FreeStyle Libre Reader

Real-time glucose readings with a painless¹ scan

 

This product is available for only insurance eligibility.

To see if you qualify, Check Insurance Eligibility >

or call us at 734-975-6668


  • CARE CREDIT IS AVAILABLE for this product.
    Find out more at checkout.
SKU: Free-Style-Reader Category:

Description

Get The FreeStyle Libre Reader Now

*Fingersticks are required for treatment decisions when you see Check Blood Glucose symbol, when symptoms do not match system readings, when you suspect readings may be inaccurate, or when you experience symptoms that may be due to high or low blood glucose.
REFERENCE: 1. Haak, Thomas, et al. “Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-treated Type 2 Diabetes: a Multicentre, Open-label Randomised Controlled Trial.” Diabetes Therapy 8, no. 1 (February 2017): 55-73. DOI: 10.1007/s13300-016-0223-6.
Indications and Important Safety Information
FreeStyle Libre 14 day Flash Glucose Monitoring system is a continuous glucose monitoring (CGM) devices indicated for replacing blood glucose testing and detecting trends and tracking patterns aiding in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments in persons (age 18 and older) with diabetes. The system is intended for single patient use and require a prescription. CONTRAINDICATIONS: Remove the sensor before MRI, CT scan, X-ray, or diathermy treatment. WARNINGS/LIMITATIONS: Do not ignore symptoms that may be due to low or high blood glucose, hypoglycemic unawareness, or dehydration. Check sensor glucose readings with a blood glucose meter when Check Blood Glucose symbol appears, when symptoms do not match system readings, or when readings are suspected to be inaccurate. The system does not have alarms unless the sensor is scanned, and the system contains small parts that may be dangerous if swallowed. The system is not approved for pregnant women, persons on dialysis, or critically-ill population. Sensor placement is not approved for sites other than the back of the arm and standard precautions for transmission of blood borne pathogens should be taken. The built-in blood glucose meter is not for use on dehydrated, hypotensive, in shock, hyperglycemic-hyperosmolar state, with or without ketosis, neonates, critically-ill patients, or for diagnosis or screening of diabetes. When using FreeStyle LibreLink app, access to a blood glucose monitoring system is required as the app does not provide one. Review all product information before use or contact Abbott toll-free 855-632-8658 or visit www.FreeStyleLibre.us for detailed indications for use and safety information. The circular shape of the sensor housing, FreeStyle, Libre, and related brand marks are marks of Abbott. ©2020 Abbott. ADC-25128 v2.0 11/20

FreeStyle Libre 14-Day Reader | Michigan USA

The Continuous Blood Glucose Monitor FreeStyle Libre 14-Day Reader

With every painless1 scan, the FreeStyle Libre 14-Day Reader displays the current glucose reading, the latest 8 hours of continuous glucose data and a trend arrow showing if glucose levels are going up down or changing slowly.

  • Glucose trend arrow

    Easy to spot ups, downs and night-time lows and see which way and how quickly glucose levels are changing.

  • Current glucose reading

    You can get your current glucose reading by an easy scan of the FreeStyle Libre sensor.

  • Food and insulin notes

    Easy to add notes to track food, insulin use, exercise, and other events.

  • 8-hour glucose history

    Get the last 8 hours of glucose data.

FreeStyle Libre Continuous Diabetic Glucose Monitor in Michigan USA

FreeStyle Libre 14-Day Reader HOW IT WORKS

1. APPLY THE SENSOR

The FreeStyle Libre sensor is applied on to the back of the upper arm with a simple, disposable device called an applicator. When the sensor is applied, a thin, flexible and sterile fibre is inserted just under the skin. It is held in place with a small adhesive pad.

2. SCAN SENSOR

To obtain a glucose reading, simply perform a quick, painless1 1-second scan of the reader over the sensor. This scan gives you more information than monitoring with blood glucose test strips, without the need for routine finger pricks1. The FreeStyle Libre system also offers optional FreeStyle Libre software to generate concise reports to assist with the analysis of glucose data.

3. GET READING

Each scan of the reader over the sensor gives a current glucose reading, the last 8-hours of glucose history, and a trend arrow showing if glucose is going up, down, or changing slowly. The reader can scan through clothing2.

FreeStyle Libre Continuous Diabetic Glucose Monitor in Michigan USA

FreeStyle Libre Continuous Diabetic Glucose Monitor in Michigan USA

Continuous Diabetic Glucose Monitor in Michigan USA

Specification for FreeStyle Libre Reader

FREESTYLE LIBRE READER SIZE 95mm * 60mm * 16mm
READER WEIGHT 65gms
READER POWER SOURCE 1 lithium-ion rechargeable battery
READER LIFE 7 days of typical use
READER MEMORY 90 days of typical use
READER OPERATING TEMPERATURE 10°C to 45°C
READER STORAGE TEMPERATURE -20°C to 60°C
READER MOISTURE PROTECTION Keep dry
READER OPERATING AND STORAGE ALTITUDE            -381 meters(-1,250 ft) to 3048 meters(10,000 ft)
READER DISPLAY TIMEOUT 6o seconds (120 seconds when test strip is inserted)
RADIO FREQUENCY 13.56 MHz
DATA PORT Micro USB
MINIMUM COMPUTER REQUIREMENTS System must only be used with EN60950-1 computers  
MEAN SERVICE LIFE 3 years of typical use
BLOOD GLUCOSE ASSAY RANGE 20 to 500 mg/dL
BLOOD KETONE ASSAY RANGE 0.0 to 144 mg/dL

Available only for Insurance Eligibility freestyle libre – Blood Glucose Monitor in Michigan USA

* Fingersticks are required if your glucose alarms and readings do not match symptoms or when you see Check Blood Glucose symbol during the first 12 hours. †Notifications will only be received when alarms are turned on and the sensor is within 20 feet of the reading device.

Indications and Important Safety Information

Freetyle Libre 14 day System: FreeStyle Libre 14 day Flash Glucose Monitoring system is a continuous glucose monitoring (CGM) devices indicated for replacing blood glucose testing and detecting trends and tracking patterns aiding in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments in persons (age 18 and older) with diabetes. The system is intended for single patient use and require a prescription. CONTRAINDICATIONS: Remove the sensor before MRI, CT scan, X-ray, or diathermy treatment.

WARNINGS/LIMITATIONS:

Do not ignore symptoms that may be due to low or high blood glucose, hypoglycemic unawareness, or dehydration. Check sensor glucose readings with a blood glucose meter when Check Blood Glucose symbol appears, when symptoms do not match system readings, or when readings are suspected to be inaccurate. The system does not have alarms unless the sensor is scanned, and the systems contain small parts that may be dangerous if swallowed. The system is not approved for pregnant women, persons on dialysis, or critically-ill population. Sensor placement is not approved for sites other than the back of the arm and standard precautions for transmission of blood borne pathogens should be taken. The built-in blood glucose meter is not for use on dehydrated, hypotensive, in shock, hyperglycemic-hyperosmolar state, with or without ketosis, neonates, critically-ill patients, or for diagnosis or screening of diabetes. When using FreeStyle LibreLink app, access to a blood glucose monitoring system is required as the app does not provide one. Review all product information before use or contact Abbott toll-free 855-632-8658 or visit www.FreeStyleLibre.us for detailed indications for use and safety information. The shape of the circle sensor unit, FreeStyle, Libre, and related brand marks are owned by Abbott. Other trademarks are the property of their respective owners. ©2020 Abbott. ADC-22410 v1.0 07/20

Go to Top